FC261 seires are touch screen thermostats. It has fashion and luxury apperance with large LCD display. It's easy and simple to set and install. They are designed to on/off control fans, valves, dampers in fan coil units or air-conditioners. Models are available for heating/cooling/ventilating control of 2-pipe or 4-pipe fan coil units.
FC261A is standard FCU type;
FC261C is networking FCU type with Modbus RS485.
Features:
Fashion and luxury appearance with high-grade large reverse LCD display
Detect and Display Room Temperature
Sensing element: NTC10
Key: capative touch
Adjust cooling / heating / vetilating and auto mode
3-speed fan (high/ medium/ low and auto)
7 days 4 periods programming
For 2-pipe or 4-pipe fan coil unit
Connect 2-wire or 3-wire valves
Key lock function to avoid any mistake operation
Celsius (°C)/Fahrenheit (F°) set
Specifications:
Power Supply: | 90-265VAC, 50/60Hz | |||||||||||
Setpoint Range: | 1-50°C ( Default 16-30°C) | |||||||||||
Set Unit: | 1°C/step | |||||||||||
Display Accuracy: | ±0.5°C | |||||||||||
Display: | LCD display touch screen | |||||||||||
Mode Setting: | Cool, Heat, Ventilating, Auto | |||||||||||
Fan Speed Adjust: | Low, Medium, High, Auto | |||||||||||
Control Performance: | On/Off | |||||||||||
Temperature Sensor: | NTC 10K | |||||||||||
Enclosure: | Fire proof ABS + anti-reflective tempered glass | |||||||||||
Loa current: | 2A (resistive load), 1A (inductive load) | |||||||||||
Networking: | RS485 Modbus | |||||||||||
Ambient Condition: | -10°C~50°C, 5-95% RH (non-condensing) | |||||||||||
Dimension: | 86*86*10.5mm | |||||||||||
Mounting: | Wall mounted with standard EU box (∮=55mm) | |||||||||||
Wiring: | Terminal block max. 1.5mm2 | |||||||||||
Installation hole distance: | 60mm | |||||||||||
Protection: | IP20 according to EN60529 | |||||||||||
Weight: | 160g |
Wiring diagram:
1. FC261A Auto changeover mode for 2-pipe fan coil unit 2. FC261A Manual mode for 2-pipe fan coil unit
3. 1. FC261A Auto changeover mode for 4-pipe fan coil unit 4. FC261C w/t Modbus RS485 auto changeover mode for 2-pipe
5. FC261C w/t Modbus RS485 manual mode for 2-pipe fan coil unit 6. FC261C w/t Modbus RS485 auto changeover mode for 4-pipe
Shipping:
1. FedEx/DHL/UPS/TNT/EMS for samples, Door-to-Door;
2. By Air or Sea or FCL for batch goods;
3. Customers designated freight forwarders or negotiable shipping methods;
Quality Control & Lead-time:
1.Incoming material inspection;
2.In-line quality control;
3.100% inspection before shipment;
4. Warranty 3 years
5.Generally within 5-7 days for samples; 55 days for bulk quantities if no stock.